Changes to the calculations and data
This page records changes that affect the interpretation or reproduction of a result. Corrections to calculations come first, followed by changes to the interface and wording. The current site version is 1.0.0 of 29 October 2026, shown above the footer on every page, including the working tools. The middle number changes when calculations or data change; the last changes when only the wording does. The engine has its own version, shown separately in the footer.
1.0.0 — 29 October 2026
This is the first site version number. Adding the version line and this history does not change the calculation engine, databases or fitted results. The corrections below were made during development, before site versions were assigned; they are included so that anyone who kept an earlier result can identify what changed and when.
27 July 2026 — Fixed sorption reactions were omitted from the sorbed fraction
The surface complexation model previously summed only the product species of reactions selected for fitting. Sorbed species defined by fixed reactions were left out. This could understate the predicted sorbed fraction, and affect a fit using fixed sorption reactions alongside fitted ones, including constants reused from My constants DB. In the recorded Hfo–Se(IV) example at pH 7, with the protonated sorbed species reaction fixed at log K 12.69, the old fraction was 0.153 (15.3%); the mass-balance result was 0.4385 (43.85%). That is a difference of 28.55 percentage points for this example, not a universal correction factor.
The fraction is now calculated as (total − aqueous)/total, which includes all sorbed species. Cases with all sorption reactions fitted agreed with the earlier sum in the audit; the single-reaction fitting examples were unaffected. If you kept a result from before 27 July that combined fixed and fitted sorption reactions, rerun it with the same inputs and review the fitted constants as well as the fractions. The historical audit does not establish a single shift in fitted log K for all such cases.
27 July 2026 — Arrival times rounded up to an output point
The transport display previously took t50 from the first output point at which C/C0 reached 0.5. The displayed pore volumes and arrival time in years therefore rounded upwards by as much as an output interval. The validation report records 0.342 years on the diffusion example’s coarse output grid against 0.300 years from an independent finite-difference solution, a 14% difference. A finer engine grid gave 0.308 years (2.7% above that independent reference).
The display now linearly interpolates between the two points bracketing C/C0 = 0.5, in both seconds and pore volumes. Retardation estimates derived from the two t50 values use those interpolated crossings too. This removes the output-point rounding rule; it does not make the numerical curve exact. The 0.300-year reference is not a claimed replacement value for every run. Earlier arrival times should be recalculated from their saved curves or by rerunning the original inputs.
Both corrections are documented in the validation audit of 27 July 2026, commit 6c1b81b, merged through PR #33. The audit records the example conditions, independent comparisons and regression tests. The source repository is private, so this page states the findings directly rather than requiring repository access.
Interface and access during development
The laboratory grew to include aqueous speciation, fitting and model comparison, reaction kinetics, and one-dimensional transport, with Excel import and export and reusable constants. These are existing capabilities, not new calculations introduced by assigning version 1.0.0. The tools were opened without sign-in in October 2026. The site moved to English and adopted the shared Radiation Lab header and footer, with narrower-screen menus and restored sharing metadata. This version adds the version line and a permanent record of changes while retaining those shared elements.
For the calculation methods, validation scope and remaining limitations, read About this laboratory. Keep the site version, engine version, selected database and its revision, and your inputs with any exported result; a site version alone is not enough to reproduce a geochemical calculation.