This tool is a research and teaching program for reproducing geochemical calculations transparently. It does not replace the qualified analyses used for licensing, safety assessment or regulatory submissions. Users are responsible for how they interpret and use the results.
Current status — limits of validation
The calculations run and are checked against independent references (see About), but the tool has not gone through the verification and validation (V&V) required of safety assessment codes used for licensing. Use the results only for research, teaching and preliminary review. Do not use them as a basis for regulatory submissions or decisions.
What this tool does not replace
This program does not replace the following:
- The safety assessment for licensing(TSPA) of a radioactive waste disposal facility, and the verified and validated (V&V) codes used for it
- Measurements and test reports from accredited testing and analytical laboratories
- Calculation notes and analysis reports submitted to regulators
- Site-specific data that must be obtained by site investigation and experiments
What this tool does is calculate and display, at the process level, the chemical processes that take place within that assessment (solubility, speciation, sorption, transport and decay). It does not produce system-level safety judgments.
Limitations of the results
Thermodynamic databases
Calculations use, unmodified, the public thermodynamic databases distributed with USGS PHREEQC (wateq4f, phreeqc, minteq.v4, llnl, sit, pitzer). Each database differs in coverage, activity model and range of applicability, and the choice of database changes the results even under the same conditions. The accuracy of each database is the responsibility of the organization that compiled it; this program does not warrant it.
Model assumptions
Equilibrium calculations rest on the assumption that chemical equilibrium has been reached under the given conditions. In real subsurface environments, reaction kinetics, flow, heterogeneity, microbial activity, colloids and other factors can cause departures from equilibrium. Parameters for sorption and transport calculations (specific surface area, site density, distribution coefficient, dispersivity, etc.) are values entered by the user, and the user must judge whether they suit the system under study.
Numerical calculation
Results may be physically meaningless if the calculation fails to converge, if a species is missing from the database, or if ionic strength or temperature is outside the range of applicability. Do not cite results that came with a warning message as they are.
Service availability
The calculation engine runs on free hosting. After a period of inactivity it goes to sleep and wakes again on the next request. The first response may then take 20–30 seconds, and calculation jobs in progress may be lost. The service may be suspended or changed without notice, and uptime is not guaranteed.
Limitation of liability
The provider is not liable for decisions made using the results of this program, or for any direct or indirect damage arising from them. When you cite results in research or reports, state the database name, input conditions and engine and database versions used, and where possible cross-check the results by an independent method.
Sources and trademarks
PHREEQC is public software developed and distributed by the U.S. Geological Survey (USGS); this program uses it as its calculation engine. This program has no affiliation with, or endorsement from, USGS, EPA, LLNL, NEA or any other organization that compiled the databases.
The tool's structure and verification records are described on the About page.