Radiation Lab M-Phreefiteq
GLOSSARY · STANDARD TERMS

Glossary

So that the terminology is not a barrier, each term has a formal definition and a one-line “In short” summary. Select a category in the pictures below to show only its terms. Headwords follow the usage of the literature, for consistent wording in papers and reports.

Ions, curves and crystals rising from an open book – illustrated glossary

32 terms

RadionuclideSolution chemistry

In short – An unstable nucleus that emits radiation and transforms into another nuclide over time.

An atomic species that undergoes radioactive decay.

  • Isotopes of one element with different neutron numbers are separate radionuclides (e.g. Se-79, Cs-137, I-129).
  • Each radionuclide has its own half-life; its chemical behavior follows that of the element.
  • Disposal safety assessments focus on long-lived, mobile radionuclides (Se-79, I-129, Tc-99, etc.).

In this tool – Assessed in the Transport simulator: chemical behavior is set by the element (e.g. Se), decay by the half-life input.

SpeciationSolution chemistry

In short – In water, one element exists in several forms (ions and complexes); speciation gives the share of each form.

The distribution of an element among its chemical forms (ions, complexes) in solution.

  • The forms present depend on pH and pe (e.g. Se as SeO₄²⁻, SeO₃²⁻, HSe⁻).
  • Solubility, sorption and mobility differ strongly between species, so speciation controls all subsequent behavior.
  • It is calculated from the equilibrium constants in a thermodynamic database.
pHFractionH₂SeO₃SeO₃²⁻Dominant species changes with pH

In this tool – In the Calculator, entering composition, pH and pe returns a speciation table and a distribution chart.

Redox potential (pe, Eh)Solution chemistry

In short – A single number that shows whether water is oxidizing (oxygen present) or reducing (oxygen nearly absent).

An indicator of the oxidation–reduction state of a solution.

  • pe is the negative common logarithm of electron activity and Eh the electrode potential (mV); at 25°C, Eh ≈ 59.16 × pe.
  • Positive values indicate oxidizing conditions (oxygen present); negative values indicate reducing conditions (deep repository).
  • For redox-sensitive elements (Se, Tc, U, etc.), speciation and solubility change by orders of magnitude with pe.

In this tool – In the Calculator and the Transport simulator, enter either pe or Eh (mV); the other is converted automatically.

Saturation index (SI)Solution chemistry

In short – Shows whether water can still dissolve more of a mineral (−) or is supersaturated and tends to precipitate it (+).

An index of the tendency of a solution to precipitate or dissolve a given mineral.

  • Defined as SI = log(IAP/K) (IAP: ion activity product; K: solubility product constant).
  • SI = 0 means equilibrium, SI > 0 supersaturation (tendency to precipitate) and SI < 0 undersaturation (tendency to dissolve).
  • Supersaturation does not imply immediate precipitation; kinetic delays can occur.
SI = 0 (equilibrium)Undersaturated(tends to dissolve)Supersaturated(tends to precipitate)e.g. SI = +0.8 → precipitation

In this tool – Shown as an SI gauge for each mineral in the Calculator; also the criterion for auto-fit (solubility limit).

Solubility limitSolution chemistry

In short – The upper limit of how much of a substance water can dissolve; any excess remains as a solid.

The maximum concentration at which an element can remain dissolved under given conditions.

  • It is set by equilibrium with a solid phase (mineral, SI = 0) and depends on pH, pe, temperature and competing ions.
  • In safety assessment it is a key input that caps the source term and is called the solubility-limited concentration.
  • Under reducing conditions, Se, Tc, U and similar elements have very low solubility limits, which strongly suppresses release.
Amount addedDissolved conc.Solubility limitExcess precipitates as mineralAll dissolved

In this tool – The 🎯 auto-fit function in the Calculator calculates the equilibrium concentration with a selected mineral directly.

Ionic strengthSolution chemistry

In short – A measure of how saline the water is, that is, how concentrated the dissolved ions are.

A measure of the total charge intensity of the ions in a solution.

  • Defined as I = ½Σmᵢzᵢ² (m: molality; z: charge number).
  • It is the reference variable for activity corrections (Debye–Hückel, SIT, Pitzer, etc.) and also affects sorption through screening of surface charge.
  • The concentration of the background electrolyte (e.g. NaCl) effectively sets the ionic strength.

In this tool – Reported in the result summary (μ) and adjusted through the choice of background electrolyte.

Charge balanceSolution chemistry

In short – Total positive and total negative charge in water must be equal, like the two pans of a balance.

The condition of electrical neutrality of a solution.

  • A physically valid solution has equal total cation and anion charge.
  • Unavoidable analytical error in the input is removed by adjusting the concentration of a selected ion (the PHREEQC charge option).
  • A charge balance error within ±5% is normally considered acceptable for water analysis data.

In this tool – Select the ion to adjust in the Calculator; the results show the charge balance error.

Thermodynamic database (TDB)Software

In short – A reference set of equilibrium constants for thousands of reactions that the Calculator draws on.

A literature-based compilation of equilibrium constants for aqueous species and minerals.

  • Coverage and values differ by organization (wateq4f: USGS trace elements; sit: NEA radioactive waste standard; etc.).
  • All equilibrium calculations depend on it, so reported results must state the database used.
  • M-Phreefiteq records a content fingerprint of each database to track version changes.

In this tool – The thermodynamic database selector on every page; the About page lists the sources of all six databases.

Sorption (adsorption)Sorption

In short – Dissolved substances attach to soil and mineral surfaces and no longer move with the water.

The binding of dissolved species to a solid surface.

  • M-Phreefiteq uses adsorption and sorption with the same meaning.
  • It is the most important natural attenuation mechanism that retards radionuclide transport.
  • It assumes reversible surface binding and is distinct from incorporation into the mineral (e.g. coprecipitation).

In this tool – Constants are estimated in the Fit laboratory; the Transport simulator calculates the resulting retardation.

Surface complexation model (SCM)Sorption

In short – A model that describes, in equations, how ions bind chemically to sites on a mineral surface.

A sorption model that describes reactions between mineral surface functional groups and dissolved species with thermodynamic constants.

  • It treats surface hydroxyl groups (≡S–OH) as reactive sites and accounts for solution chemistry (pH, ionic strength, competing ions) in a thermodynamically consistent way.
  • Models differ in their treatment of the electrical double layer: NEM (non-electrostatic), DDL (diffuse double layer), CCM (constant capacitance), etc.
  • Unlike the distribution coefficient (Kd) approach, it allows extrapolation to changed conditions, which is its main advantage.

In this tool – A model option in the Fit laboratory; transport calculations use NEM for numerical stability.

Sorption edgeSorption

In short – A curve of the fraction sorbed measured at stepwise pH values; sorption changes sharply between acidic and alkaline conditions.

The pH range (curve) over which the sorbed fraction changes sharply.

  • Anions tend to sorb strongly at low pH and desorb as pH rises; cations show the opposite trend.
  • The position and slope of the edge are sensitive to the surface complexation constants, which makes edges the best experimental data for parameter estimation.
  • Edges are usually measured by varying only pH at constant total concentration and constant ionic strength.
pHFraction sorbedEdge: log K-sensitiveAnion type (sorbs at low pH)

In this tool – The input data format of the Fit laboratory (pH vs. fraction sorbed); all three examples are sorption edges.

Surface complexation constant (log K)Sorption

In short – A number for how readily a reaction proceeds; the larger it is, the stronger the binding or the more readily the species forms.

The equilibrium constant of a surface complexation reaction, expressed as a common logarithm.

  • A larger value indicates a stronger reaction (sorption).
  • It is estimated by fitting a model to experimental sorption edges and should be reported with its uncertainty (±).
  • Values for the same reaction depend on the surface complexation model applied (NEM/DDL/CCM), so the model must be stated.

In this tool – The target of parameter estimation in the Fit laboratory; saved to My constants DB for reuse in transport calculations.

Surface site densitySorption

In short – How many sites per m² of mineral surface are available for binding.

The total amount of reactive sites (functional groups) on a solid surface.

  • Calculated as solid concentration (g/L) × specific surface area (m²/g) × site density (sites/nm²).
  • A site density of 2–3 sites/nm² is usually applied (Dzombak & Morel recommend 2.31).
  • It sets the upper limit of sorption capacity and directly affects the retardation factor.
  • Notation: descriptive text uses 'site' throughout; model names (two-site model), PHREEQC identifiers (Hfo_wOH, etc.) and units (sites/nm²) keep their original form.

In this tool – The site calculator in the Fit laboratory converts material properties into site concentrations.

Goodness of fit (R², WSOS/DF)Sorption

In short – A score for how closely the model curve follows the experimental points.

Statistical indicators of how well a model reproduces the experimental data.

  • R² closer to 1 is better; 0.95 or above is normally considered a good fit.
  • WSOS/DF is the conventional FITEQL metric; values of 0.1–20 are considered acceptable.
  • BIC and AIC penalize the number of parameters and are used to compare models; lower is better.

In this tool – The fit results show the value of each metric with a rating and advice for improvement.

Advection / dispersionTransport

In short – Being carried by the flow (advection) and spreading while mixing (dispersion), like ink dropped into a river.

Transport of a solute by groundwater flow (advection) and its spreading by mixing (dispersion).

  • Advection is movement at the mean flow velocity; dispersion is the smoothing of the concentration front by pore-scale velocity variations and molecular diffusion.
  • Dispersivity (m) sets the magnitude of dispersion and tends to increase with travel distance.
  • These are the controlling mechanisms of transport in rock fractures and aquifers where groundwater flow is significant.

In this tool – The 'Column flow' mode of the Transport simulator couples advection, dispersion and sorption.

Diffusion-dominated transportTransport

In short – Without any flow, solutes spread slowly from high to low concentration, like a drop of ink in a glass of water.

A transport regime controlled by molecular diffusion along a concentration gradient.

  • The effective diffusion coefficient De (m²/s) sets the transport rate; the characteristic time is approximately L²/De.
  • Compacted bentonite buffer has very low permeability, so diffusion is the only significant transport pathway.
  • For anions, De tends to be even lower because of exclusion by the negative charge of clay surfaces.
Advection(flow-dominated)Diffusion(concentration gradient)

In this tool – The 'Buffer diffusion' mode of the Transport simulator, with the time axis in years.

Breakthrough curve (BTC)Transport

In short – A curve over time of when, and how much, solute starts to appear at the outlet of a column (soil layer).

A curve of concentration at the outlet of a medium versus time (or pore volume).

  • It is expressed as relative concentration (C/C₀), the outlet concentration divided by the inlet concentration.
  • The further the curve shifts to the right, the greater the retardation.
  • The slope of the curve reflects the magnitude of dispersion; the half-concentration point (t₅₀) indicates the mean arrival time.
Pore volumes (PV) or timeC / C₀C/C₀ = 0.5Rf = t₅₀ ratioTracerRadionuclide(sorbing)

In this tool – The standard output of the Transport simulator, overlaying the tracer and radionuclide curves for comparison.

Pore volume (PV)Transport

In short – The volume of water needed to replace the water in the pores of a column once; the basic unit of transport time.

A dimensionless time unit in which 1 equals the flow volume needed to displace the entire pore space of the medium once.

  • By definition, a conservative tracer reaches half the inlet concentration at the outlet at about 1 PV.
  • Normalizing time in this way allows comparison between experiments at different flow rates and scales.
  • Dividing the radionuclide t₅₀ (PV) by the tracer t₅₀ (≈1 PV) gives the retardation factor.

In this tool – The horizontal axis in Column flow mode; the 'Simulation range' input sets the displayed range.

Conservative tracerTransport

In short – A reference substance that binds to nothing and moves exactly with the water; it is the yardstick for retardation.

A reference substance that moves with the groundwater without sorption or reaction.

  • Br⁻, Cl⁻ and tritiated water (HTO) are used in experiments.
  • It reflects only the hydraulic properties of the medium (velocity, dispersion), so it is the reference for separating sorption effects.
  • M-Phreefiteq automatically runs a calculation under the same conditions with sorption excluded.

In this tool – The Transport simulator calculates a tracer curve on every run as the reference for comparison.

Retardation factor (Rf)Transport

In short – How many times later a solute arrives than the water; with Rf = 10, a distance that water travels in 1 year takes 10 years.

The factor by which sorption delays the arrival of a radionuclide relative to a tracer.

  • Calculated as Rf = radionuclide t₅₀ ÷ tracer t₅₀.
  • Rf = 1 means no retardation; Rf = 10 means that arrival takes 10 times as long.
  • It increases with sorption capacity (site concentration) and sorption strength (log K).
Pore volumes (PV) or timeC / C₀C/C₀ = 0.5Rf = t₅₀ ratioTracerRadionuclide(sorbing)

In this tool – The key output of the Transport simulator and the criterion for the result interpretation text.

Half-lifeTransport

In short – The time it takes for radioactivity to fall by half; each time this period passes, half of what remains is gone.

The time required for half of a radionuclide to decay.

  • Decay is described as a first-order reaction with decay constant λ = ln2/t½.
  • If the travel time is comparable to or longer than the half-life, decay significantly reduces the arriving concentration.
  • Se-79: 3.27×10⁵ years; I-129: 1.57×10⁷ years; Cs-137: 30.1 years.

In this tool – An input in the advanced settings of the Transport simulator; the reduction by decay appears in the breakthrough curve.

Source termSafety assessment

In short – The starting condition: what is released from the canister, from when, and how much.

The amount and concentration of radionuclides released from the disposal canister at the start of transport.

  • The solubility limit caps the source term concentration.
  • It consists of three elements: canister lifetime, release rate and solubility limit.
  • It is the starting point of the safety assessment calculation chain.

In this tool – The solubility limit (auto-fit) result from the Calculator is the basis for estimating the source term concentration.

Buffer (bentonite buffer)Safety assessment

In short – A clay layer around the canister that transmits almost no water and retains radionuclides like a protective sponge.

The engineered barrier material that fills the space between the disposal canister and the host rock.

  • Compacted bentonite is normally used; the required properties are low permeability, high swelling capacity and high sorption capacity.
  • It blocks groundwater flow and so limits radionuclide transport to diffusion.
  • In Korea, Gyeongju bentonite is being studied as a candidate material.

In this tool – Corresponds to the 'Buffer diffusion' mode of the Transport simulator and the bentonite example in the Fit laboratory.

Multi-barrier systemSafety assessment

In short – Successive barriers such as canister, clay and rock; if one fails, the next one still holds.

The basic concept of deep geological disposal, in which engineered and natural barriers are placed in series.

  • It consists of the sequence disposal canister → buffer → near-field rock → far-field rock.
  • It is designed so that loss of performance in one barrier is compensated by the others.
  • Quantifying the retention performance of each barrier is the role of geochemical calculations.

In this tool – Shown in the full-cycle cross-section and the multi-barrier inset on the About page.

PHREEQCSoftware

In short – The computing core of this laboratory: the world-standard program for water chemistry, run here unmodified on the server.

An aqueous geochemistry program developed and maintained by the US Geological Survey (USGS).

  • The name stands for pH–REdox–EQuilibrium (written in C); its predecessor is PHREEQE (1980).
  • It supports speciation, saturation indices, mineral equilibria, ion exchange, surface complexation, 1D reactive transport and inverse modeling.
  • It is the de facto international standard in groundwater geochemistry and disposal safety assessment.
  • This laboratory runs the original USGS IPhreeqc native library (3.8.6) directly, not an approximate reimplementation.

In this tool – Runs behind every calculation on the site; the phreeqc version shown below each result is the evidence.

FITEQLSoftware

In short – The original tool for fitting curves to experimental points to obtain the binding strength (log K); our Fit laboratory continues this work on the web.

The classic standard program for estimating equilibrium constants (log K) from experimental data by nonlinear least squares.

  • Developed by Westall (1982); maintenance stopped after the final version 4.0 (Herbelin & Westall, 1999).
  • Many surface complexation constants in the literature were derived with it, and it is the origin of the WSOS/DF goodness-of-fit convention.
  • The M-Phreefiteq Fit laboratory recasts the same problem with global optimization (differential evolution) and modern statistics (R², BIC, WSOS/DF).

In this tool – The whole Fit laboratory is a web successor of the FITEQL workflow; see section 02 of the About page.

MINTEQA2Software

In short – The original program for entering components as a table; the 'M' in this laboratory's name comes from it, and its database is included.

An equilibrium speciation model distributed by the US Environmental Protection Agency (EPA), known for its validated thermodynamic database and tabular input.

  • Its lineage goes back to REDEQL (1972) and MINEQL (1976) at MIT; the EPA version (1991) became the standard for environmental assessment.
  • Its successor, Visual MINTEQ (KTH, Sweden), is still actively maintained.
  • This laboratory includes minteq.v4.dat (the EPA MINTEQA2 v4 database), so calculations can use the same data set.

In this tool – Available as minteq.v4.dat in the thermodynamic database selector of the Calculator.

Reaction kineticsSolution chemistry

In short – Equilibrium calculations tell where a system ends up; kinetics tells how long it takes, separating reactions that finish in a day from those that take ten thousand years.

The field that deals with reaction rates on the way to equilibrium; PHREEQC integrates the rate laws of the KINETICS/RATES blocks over time.

  • Mineral dissolution rates are expressed as functions of surface area, saturation state (1−Ω) and the activities of catalyzing ions (e.g. the PWP rate law for calcite).
  • As SI approaches 0, the driving force decreases and the rate slows – the reason why the curve approaches the equilibrium value asymptotically.
  • Radioactive decay is the simplest first-order kinetics (rate = −λN), with half-life t½ = ln2/λ.

In this tool – The Kinetics page calculates built-in rate laws (calcite, pyrite, etc.), first-order removal and decay chains along a time axis. The 'Kinetics (contact time)' model in the Fit laboratory estimates rate constants from experimental data.

Pseudo-first-order / pseudo-second-order (PFO/PSO)Sorption

In short – Two equations used to decide how long a sorption test must be shaken to reach equilibrium; the one that fits the data better is chosen by goodness of fit.

The standard empirical equations of sorption kinetics for uptake versus contact time – PFO (Lagergren 1898) assumes an exponential approach, PSO (Ho & McKay 1999) a hyperbolic approach.

  • PFO: q(t) = qₑ(1−e^(−k₁t}) – assumes that uptake is proportional to the remaining vacant sites.
  • PSO: t/q versus t is linear – often interpreted as control by chemisorption.
  • Both are analytical (empirical) equations and do not prove a mechanism – models are compared with goodness-of-fit metrics such as R² and AIC.

In this tool – The 'Kinetics (contact time)' model in the Fit laboratory – estimates the rate constant k, equilibrium fraction f_e and half-uptake time t½; the results state that it is an analytical model.

Dual porosity (mobile–immobile, MIM)Transport

In short – In granite, water flows only through narrow fractures while the water in the rock is stagnant; radionuclides diffuse into the stagnant water and return slowly, which causes late arrival and a long tail.

A transport model that divides the medium into a mobile zone (fractures) and an immobile zone (rock matrix) linked by first-order exchange (mobile–immobile model).

  • Three parameters: exchange coefficient α (1/s), mobile porosity θm and immobile porosity θim.
  • The mean arrival of a conservative tracer is delayed by a factor of (θm+θim)/θm, independent of α (α sets the shape of the tail).
  • In crystalline rock most of the sorption capacity lies in the matrix, so matrix diffusion is the gateway to effective retardation.
  • Implemented with the PHREEQC -stagnant first-order exchange approximation – the standard framework for fractured media such as KURT granite.

In this tool – The 'Dual porosity (fracture–matrix)' medium in the Transport simulator, with a matrix sorption option. Regression tests fix the agreement of tracer moments with theory (docs/13).

Decay chain (Bateman equations)Safety assessment

In short – Radioactive material does not vanish but turns into other nuclides – as Am-241 decreases, Np-237 is produced, and the total is conserved.

The analytical solution for a chain in which decay of a parent produces and accumulates daughters – the parent decays exponentially, and the daughter is set by the balance between production and its own decay.

  • Two-member chain: parent N₁ = N₀e^(−λ₁t), daughter N₂ = N₀·λ₁/(λ₂−λ₁)·(e^(−λ₁t) − e^(−λ₂t)).
  • With a short-lived parent and a long-lived daughter (e.g. Am-241 → Np-237), the focus of long-term safety shifts to the daughter.
  • In transport calculations, parent and daughter are retarded separately according to their own chemistry (sorption, solubility) – the reason why 'it has decayed away' is not an answer.

In this tool – The 'Daughter nuclide' input of the Transport simulator and the 'Decay chain' reaction on the Kinetics page – regression tests fix the agreement of engine results with the Bateman solution (docs/13).

Fit uncertainty (confidence interval)Software

In short – 'log K = 7.06' alone is not enough for a paper or an assessment; it needs '± how much?'. A 95% interval means that in 95 of 100 repeated experiments the value would fall within it.

The range over which an estimated constant can vary because of scatter in the data – reported as standard error (±) and 95% confidence interval.

  • The standard error is calculated from the curvature (Jacobian) near the solution; 95% CI = estimate ± t(0.975, DF)·standard error.
  • Bootstrapping refits tens to hundreds of times on randomly resampled residuals – it cross-checks the CI without distributional assumptions.
  • If a parameter sits on a bound of the search range, curvature-based uncertainty is meaningless – this laboratory gives an explicit warning in that case.
  • A wide CI means that the data do not constrain that parameter well – extending the measurement range (concentration, pH) is often the answer.

In this tool – ± standard error and 95% CI (always) and bootstrap CI (optional) in the Fit laboratory results, the shaded confidence band on the curve, and the CI column of the Excel report (docs/14).