New here? – How to use this page
Fits the same experimental data with different reaction sets (candidate models) and uses the BIC statistic to compare which model explains the data best. This page answers questions such as 'one reaction or two?'
- Enter common conditions – Enter the data, surface and solution conditions shared by all candidates at the top.
- Set up candidate models – Add models with [Add candidate model] and define a different reaction set for each candidate (e.g., 1-site vs 2-site).
- Run and interpret the comparison – The model with the lowest BIC is marked 'Best'. ΔBIC > 10 indicates a clear difference; ΔBIC of 2–6 a weak difference.
Model comparison
How to read this reaction
At low pH the surface hydroxyl group takes up a proton and the surface acquires a positive charge (+). Anions are then readily attracted.
The larger log K, the higher the pH up to which the surface stays positively charged (surface acidity constant).
How to read this reaction
At high pH the surface hydroxyl group releases a proton and the surface acquires a negative charge (−). Anions are then repelled.
The larger (less negative) log K, the lower the pH at which negative charge develops (surface acidity constant).
How to read this reaction
The surface hydroxyl group (≡Mag–OH) binds selenite ion (SeO3-2) from solution and forms a surface complex. The surface OH leaves as water (ligand exchange). Protons are consumed, so sorption is favored at lower pH (anion-type edge: sorption decreases as pH rises).
The larger log K, the stronger the sorption. This is the constant the fit estimates.
What this page compares
Several surface complexation models can be built for the same sorption data. The quality of the fit depends on whether the sorption sites are treated as one type or two, and on which surface reactions are included. This page applies the same database and measured data to every candidate, fits the reaction set defined for each candidate, and collects the results in one table. The table lists the number of parameters (k), the coefficient of determination (R²) and the adjusted coefficient of determination, RMSE, BIC, and ΔBIC, the difference from the lowest BIC.
How to read the results
Adding parameters almost always raises R², so choosing a model by R² alone leads toward overfitting. BIC, defined as n·ln(SSR/n) + k·ln(n), weighs the reduction in residuals against a penalty for the number of parameters. Choose the candidate with the lowest BIC first; candidates with ΔBIC below 2 cannot be distinguished by the data. A ΔBIC above 10 indicates a clear difference. BIC can only compare candidates fitted to the same data, however. Even for the best candidate, if the residuals are biased to one side along pH or concentration, the reaction set itself needs to be reconsidered. Refit the constants of the best model in the Fit laboratory and check their uncertainty and residuals.