Radiation Lab M-Phreefiteq

Redox: why the same element moves differently

In a disposal safety assessment, some radionuclides are treated as practically immobile and others as moving with the water. The element alone does not always decide which. For technetium, selenium, uranium and neptunium, a change in oxidation state changes solubility and sorption on minerals by several orders of magnitude. This note describes where that difference comes from, how the redox state of deep groundwater is expressed, which assumptions the assessment of the Korean reference disposal system relies on, and which scenarios could undermine those assumptions.

All figures in this note come from the published literature; the sources are listed at the end. Calculated values are derived from those figures with the equations given on this page. The note is intended for education and research and makes no judgment on the safety of any specific disposal facility.

Effects of oxidation state

The form in which an element occurs in water depends strongly on its oxidation state. The four elements of most concern for disposal follow a common pattern. Oxidized forms occur as anions or large complex ions that dissolve readily and sorb weakly on mineral surfaces; reduced forms precipitate as sparingly soluble solids or sorb strongly on surfaces.

  • Technetium – Under oxidizing conditions it occurs as heptavalent pertechnetate (TcO₄⁻) and is hardly sorbed; reduced to Tc(IV), it forms sparingly soluble oxides and hydrous oxides.
  • Selenium – Selenate (Se(VI)) and selenite (Se(IV)) are dissolved and mobile; elemental selenium (Se(0)) and selenide (Se(−II)) are very sparingly soluble.
  • Uranium – The hexavalent uranyl ion forms strong carbonate complexes and stays in solution; U(IV) remains as sparingly soluble solids such as uranium dioxide.
  • Neptunium – The pentavalent neptunyl ion is highly mobile; Np(IV) has low solubility and low mobility.

Iodine falls outside this list for a different reason. Under repository conditions it occurs mainly as iodide, which is soluble and non-sorbing almost regardless of the redox state. Iodine-129 is therefore a baseline radionuclide that gains no benefit from reducing conditions.

pe and Eh – numbers for the redox state

The redox state of a solution can be expressed through the activity of electrons. Just as pH is the negative logarithm of the hydrogen ion activity, pe is the negative logarithm of the electron activity. Higher pe means more oxidizing, lower pe more reducing. At 25 ℃, pe relates to Eh (in volts), the redox potential expressed as an electrode potential, as follows.

Eh = (RT ln10 / F) · pe ≈ 0.05916 V × pe

Here R is the gas constant, T the absolute temperature and F the Faraday constant. The KURT-type reconstructed reference water used in the granite fracture examples of this lab is set to pH 8.3 and pe -4; with the equation above this corresponds to an Eh of about -0.24 V. This value was reconstructed from semi-quantitative constraints in the published sources and was not measured directly. A field-measured Eh depends on the redox couple to which the electrode responds, and in groundwater where several couples are not in equilibrium, a single Eh can hardly represent the whole system. Assigning a single pe in a calculation is itself an assumption.

Origin of reducing conditions in deep granitic groundwater

Rainwater infiltrating from the surface carries oxygen but loses it as it descends through the rock, because minerals containing ferrous iron, sulfide minerals, organic matter and the microorganisms that mediate these reactions consume the oxygen. In borehole data from the KAERI Underground Research Tunnel (KURT) at the KAERI site in Daejeon, the groundwater evolves from a shallow Ca-HCO₃ type to a deep Na-Ca-HCO₃ type, and the deep boreholes show a reducing environment with low dissolved oxygen and lowered Eh. Near the surface, infiltrating oxidizing rainwater creates multiple redox fronts.

Residence times of the deep groundwater estimated from carbon-14 ages are 2,000–6,000 years. This also means that the water has been in contact with the rock long enough to use up its oxygen. Fracture-filling minerals identified in drill cores include calcite, illite, laumontite, chlorite, epidote, montmorillonite and kaolinite; among these, ferrous-iron-bearing minerals such as chlorite react with oxygen and contribute reducing capacity.

Assumptions of the Korean assessment

The KRS+ safety assessment set the reference geochemical conditions to reducing groundwater with negative Eh and pH 7–10. This assumption enters the assessment at many points. Technetium was assessed as dominated not by pertechnetate but by the neutral Tc(IV) hydroxo complex; as a result, technetium, uranium and neptunium were assigned a high buffer Kd of 39 m³/kg. The solubility limits are likewise KURT-condition values derived for the same conditions.

ElementBuffer Kd (m³/kg)Rock Kd (m³/kg)Solubility limit (mol/m³)
Tc395.3×10⁻²1.0×10⁻⁵
U395.3×10⁻²5.0×10⁻⁵
Np395.3×10⁻²2.0×10⁻⁵
Se03.0×10⁻⁴1.0×10⁻⁴
I00Unlimited

Ju et al. 2020, Table 4 (Kd, values adopted from SR-Site) and Table 5 (solubility, KAERI radionuclide database for KURT conditions). The solubility unit mol/m³ equals 10⁻³ mol/L – when comparing with the calculator of this lab (mol/kgw), watch for the factor of 1,000.

The dose results rest on the same assumption. The peak dose in the assessment came from iodine-129 (about 14,000 years, 8.19×10⁻⁴ mSv/yr), and the paper states that the contributions of the transuranic elements and uranium are negligible because of their low mobility under reducing conditions. In other words, the redox-sensitive radionuclides are absent from the dose precisely because reducing conditions are assumed. This is why it matters when, where and for how long this assumption could fail.

Oxidizing perturbation scenario

The repository is open to air during construction and operation. Immediately after closure, oxygen introduced during that period remains in the buffer, the backfill and the surrounding rock, and sulfide minerals on fracture surfaces exposed by excavation oxidize on contact with oxygen. Pyrite oxidation releases hydrogen ions and lowers the pH:

FeS₂ + 15/4 O₂ + 7/2 H₂O → Fe(OH)₃ + 2 SO₄²⁻ + 4 H⁺

Scenario 03 of this lab follows this chain as an example. Oxygen intrusion during operation leads to pyrite oxidation and a drop in pH, and the resulting abrupt changes in the solubility of technetium, selenium and uranium are examined with the kinetics tool and the calculator. Over the same period, the trapped oxygen is consumed by sulfide minerals, ferrous iron minerals, organic matter and microorganisms, and the system returns to reducing conditions. The questions are how long the oxidizing period lasts, how far it extends, and whether the canisters remain intact during it. If the canisters remain intact throughout the oxidizing period, the oxidizing perturbation has no effect on radionuclide migration.

Selenium and technetium as special cases

Selenium-79

The half-life of selenium-79 is 327,000 years. In the KRS+ assessment, selenium has a buffer Kd of 0, a rock Kd of 3.0×10⁻⁴ m³/kg and a solubility limit of 1.0×10⁻⁴ mol/m³. A buffer Kd of 0 means that the buffer does not retain selenium by sorption; in that case the solubility limit is what constrains selenium release. The low solubility under reducing conditions comes from sparingly soluble solids such as elemental selenium or selenides, so if oxidation dissolves those solids, selenium converts to anions and is constrained by neither sorption nor solubility.

Technetium-99

The half-life of technetium-99 is 211,000 years. Under reducing conditions, Tc(IV) is assigned a low solubility (1.0×10⁻⁵ mol/m³) and a high Kd, but both nearly vanish once it is oxidized to pertechnetate. Reduction to Tc(IV) is known to proceed readily on the surfaces of ferrous iron minerals; conversely, Tc can be reoxidized if oxygen returns. The same element thus moves between two extremes, so the assessment values for technetium are more accurately read as properties of the assumed redox state than of the element itself.

A comparison with iodine-129 (15.7 million years) makes the difference clear. Iodine sorbs weakly and dissolves readily under any conditions, so it is less sensitive to the assumption; selenium and technetium shift toward iodine-like behavior when the assumption changes. Neptunium-237 (2.144 million years) raises the same question between Np(V) and Np(IV).

Points to note in calculations

  • Thermodynamic databases differ in the elements they cover. The default wateq4f database of this lab contains no Tc, Np or Am, so actinides and technetium are calculated with llnl or sit (NEA-TDB lineage).
  • Fixing a single pe assumes that all redox couples are in equilibrium. In real groundwater the couples react at different rates and may not be in equilibrium.
  • Match the unit of the solubility limit table (mol/m³) with that of the calculator (mol/kgw).
  • Results for redox-sensitive radionuclides are best examined over the full assumed pe range – a result for a single value is the result of that assumption.

How the distribution coefficient responds to these conditions is covered in the distribution coefficient note, and buffer porewater chemistry in the buffer note.

Calculations in this lab

  • Calculator – Calculates speciation and solubility of Tc, Se and U as pe varies (actinides with the llnl and sit databases).
  • Kinetics – Estimates how long oxygen takes to be consumed, using rate laws for pyrite oxidation and organic matter degradation.
  • Release scenarios – Scenario 03 (oxidizing perturbation) works through the questions of this note in an example.

Sources

  1. Ju et al., Safety Assessment on Long-term Radiological Impact of the KRS+, JNFCWT 18(S) 75–87 (2020) — geochemical conditions, Kd, solubility, dose
  2. Cho et al., A Safety Case of the Conceptual Disposal System for Pyro-processing HLW (KAERI) — original source of the KURT-condition solubilities
  3. Geochemistry of KURT groundwater considering water–rock interaction (in Korean), J. Kor. Rad. Waste Soc. 10(3) (2012) — water type, pH, semi-quantitative constraints
  4. Geochemical characteristics of KURT groundwater considering water–rock interaction (in Korean; abstract) — fracture-filling minerals
  5. NNDC NuDat 3 — half-life cross-check

Further reading